RF & Microwave T-Matched Pick-Off Tees
TAYLOR MICROWAVE, INC. | RF & MICROWAVE
T-Matched Pick-Off Tees
Low-loss stripline pick-off tees for RF and microwave signal monitoring.

High-Performance Pick-Off Tees
Taylor Microwave T-Matched Pick-Off Tees are low-cost, high-performance stripline devices
designed to provide a controlled RF pick-off signal while maintaining low insertion loss
and repeatable performance. Standard models are available for broadband RF and microwave
applications, with custom frequency bands and electrical specifications available.
T-Matched Pick-Off Tee Configurations
Taylor Microwave offers several T-matched Pick-Off Tee configurations to meet different RF matching and pick-off requirements.

*R3 is optional for matching J3.
POT-XXG SMA Series
Standard SMA Pick-Off Tee models are available for broadband RF and microwave applications.
Custom frequency bands and electrical specifications are also available.
| Pick-Off Tees No Match P/N | (1) Frequency Range (GHz) | Insertion Loss Max. (db) | (2) Pick-Off (db) | VSWR IN/OUT Max. | (3) Input Power (Watts Max.) | R2 (Ohms) |
|---|---|---|---|---|---|---|
| POT-XXG | User Defined Contact TMI | User Defined Contact TMI | User Defined Contact TMI | |||
| POT-20G-11 | DC-20 | 1.8 | 10.9 +/-1 | 1.7/1.7 | 1 | 100 |
| POT-20G-20 | DC-20 | 1.1 | 19.6 +/-1 | 1.5/1.5 | 1 | 400 |
| POT-20G-15 | DC-20 | 1.2 | 14.5 +/- 1 | 1.5/1.5 | 1 | 200 |
| POT-30G-15 | DC-30 | 1.2 | 15 +/- 1 | 1.6/1.6 | 1 | 200 |
| POT-40G-15 | DC-40 | 2.5 | 15 +/- 1.25 | 1.5/1.5 | 1 | 200 |
J1 / J2 Matched Pick-Off Tees
Matched J1/J2 models provide controlled pick-off performance with matched main-line ports
for demanding RF and microwave applications.
| Pick-Off Tees J1/J2 Matched P/N | (1) Frequency Range (GHz) | Insertion Loss Max. (db) | (2) Pick-Off (db) | VSWR IN/OUT Max. | (3) Input Power (Watts Max.) | R1 (Ohms) | R2 (Ohms) |
|---|---|---|---|---|---|---|---|
| POT-XXG | User Defined Contact TMI | User Defined Contact TMI | User Defined Contact TMI | User Defined Contact TMI | User Defined Contact TMI | ||
| POT-26G-15A | DC-26 | 3.1 | 14.9 +/-1.25 | 1.5/1.5 | 0.500 | 5 | 200 |
| POT-26G-20A | DC-26 | 2.5 | 20.5 +/-2.0 | 1.5/1.5 | 0.500 | 2.5 | 400 |
POT-F Series — 75 Ohm Pick-Off Tees
The POT-F Series provides 75-ohm pick-off tee configurations for broadband applications through 3 GHz.
| Pick-Off Tees P/N | (1) Frequency Range (GHz) | Insertion Loss Max. (db) | (2) Pick-Off (db) | VSWR IN/OUT Max. | (3) Input Power (Watts Max.) | R1 (Ohms) |
|---|---|---|---|---|---|---|
| POT-XXG | User Defined Contact TMI | User Defined Contact TMI | User Defined Contact TMI | |||
| POT-15-F | DC-3.0 | 1.1 | 15 +/- 0.50 | 1.25/1.25 | 1 | 300 |
| POT-20-F | DC-3.0 | 0.70 | 19.5 +/- 0.50 | 1.15/1.15 | 1 | 600 |
Taylor Sense-Tee for Bias Voltage Sensing
The Taylor Sense-Tee samples the voltage on a 50 Ω RF line through
a series pick-off resistor. Connect J1 to the bias tee’s RF+DC output
and J2 to the device under test. Connect J3 to a
50 Ω oscilloscope input or a 10 MΩ voltmeter. Use a DC-coupled oscilloscope
input to measure DC bias.
Voltage Scaling at J3
The pick-off resistor and the instrument’s input resistance form a voltage divider.
Multiply the measured voltage by the scale factor k to calculate the voltage at the tap.
Rpick-off = (k − 1) Rinput
k =
Vtap
Vmeasured
-
50 Ω oscilloscope input.
A 2 kΩ pick-off resistor gives a 41:1 voltage ratio.
For a 10:1 ratio, use a 450 Ω pick-off resistor. -
10 MΩ voltmeter.
A 2 kΩ pick-off resistor gives a DC scale factor of 1.0002.
A 5.000 V tap voltage reads approximately 4.999 V before accounting for meter accuracy.
ST-A01 uses a 3 kΩ pick-off resistor.
Its nominal resistive divider ratio is 61:1 with a 50 Ω input,
and its DC scale factor is 1.0003 with a 10 MΩ voltmeter.
The 10 MΩ value applies to DC. For RF and fast pulses, the instrument’s input
capacitance and the test connection also affect the measured voltage.
P/N | Frequency Range (GHz) | Insertion Loss Max. (db) | Pick-Off (db) | VSWR IN/OUT Max. | Input Power (Watts Max.) | R1 (Ohms) |
|---|---|---|---|---|---|---|
| ST-AXX | DC-20 | X.XX | XX.XX | X.XX/X.XX | XX | XXXX |
| ST-A01 | DC-20 | 1.0 | >30 | 1.25/1.25 | 10 | 3000 |
Please specify your frequency range, DC voltage, current, and voltage-sensing requirements.
Custom Pick-Off Tee Designs
Taylor Microwave can provide custom frequency bands and optimized electrical specifications
to meet your application requirements.
- Custom frequency ranges
- Custom pick-off values
- Optimized insertion loss and VSWR
- High-power configurations
- Custom connector configurations
- Custom stripline designs
Need a Custom Pick-Off Tee?
Contact Taylor Microwave for custom frequency bands, pick-off values, power levels,
connectors, and optimized specifications.